ustrip-3.2.js (Javascript program and Input form used in this page.)
Formulas used
Micro strip line impedance
where,
Open end effect length
Rightangle bend compensation. Valid for w / h ≥ 0.25, ϵr ≤ 24, ± 4 % accuracy.
Buried microstrip line
Differencial impedance of side coupled microstrip line
APPENDIX
Example of field solver results (simulation box width W = 12 h + 4 t + 2 s + w, box height H = 8 h + t)
Length unit in [ grid ].
w = 200, h = 200, t = 35, b = 0, ϵr=4.7, W = 2740, H = 1635 : Z0 ≃ 63.303 Ω w = 200, h = 200, t = 35, b = 55, ϵr=4.7, W = 2740, H = 1635 : Z0 ≃ 58.388 Ω
Pseudo color visualization of absolute value of the electric field.
REFERENCE
H. A. Wheeler, "Transmission-line properties of a strip on a dielectric sheet on a plane",
IEEE Trans. Microwave Theory Tech., vol. MTT-25, pp.631-647, Aug. 1977.
R. J. Douville and D. S. James, "Experimental study of symmetric microstrip bends and their compensation",
IEEE Trans. Microwave Theory Tech., vol. MTT-26, pp. 175-182, Mar. 1978
James A. Mears, "Transmission Line RAPIDESIGNER Operation and Applications Guide",
National Semiconductor Application Note, AN-905, May.1996
Brian C. Wadell, "Transmission Line Design Handbook", Artech House, Inc., 1991, ISBN 0-89006-436-9