Resistance → Temperature conversion [SOLVER] [Pt100] Resistance [R] [Temp]
Temperature → Resistance conversion [SOLVER] [Pt100] Temperature [Temp] [R]
Variables
MEM "R" : resistance [Ω]
MEM "Temp" : temperature [°C]
Callendar-Van Dusen equation:![]()
Pt100 Resistance V.S. Temperature
RT : Resistance [Ω] at temperature T [°C] R0 : Resistance [Ω] at 0 °C T : Temperature in °C A : 3.9083 × 10-3 B : -5.775 × 10-7 C : -4.183 × 10-12 | -200 ≤ T < 0 : 0 | 0 ≤ T ≤ +650 The equation is applicable for -200 ≤ T ≤ +650
"Pt100" : Pt100-1997 RTD functionDownload 'Pt100' (raw program file for the Free42)
To be used in the SOLVER 01 LBL "Pt100" 02 MVAR "Temp" 03 MVAR "R" 04 RCL "Temp" 05 ENTER 06 ENTER 07 ENTER 08 X>0? 09 100 10 100 11 - 12 -4.183E-12 13 × 14 × 15 -5.775E-7 16 + 17 × 18 3.9083e-3 19 + 20 × 21 1 22 + 23 100 24 × 25 RCL- "R" 26 .END.
[1] JIS C 1604-1997
[2] IEC 60751 Amd.2-1995